Powder-blend check, internal 10-capsule worksheet and 20-capsule test under Ph. Eur. 2.9.5, plus separate internal powder screening.

Frequently asked questions about Capsule and powder quality control

How do I check the powder mixture's internal mass balance?

Enter the planned total powder mass and the mass actually measured. The tool calculates the percentage difference and compares it with its internal 2.0% working limit. This mass balance does not establish mixture homogeneity or constitute a pharmacopoeial release test.

Which capsule and divided-powder checks can I perform?

The tool offers an internal powder mass balance, a worksheet for 10 filled capsules (using the mean of 10 empty shells weighed together), a 20-capsule uniformity-of-mass check with individual shell tares and an internal screen of 10 divided powder units. For undivided powders, only the mass balance is available.

How do the 10-capsule and 20-capsule checks differ?

The 10-capsule worksheet estimates each fill mass using a single mean empty-shell tare and internal limits. The 20-capsule check subtracts each capsule’s own empty-shell mass and assesses mass uniformity under the applicable Ph. Eur. method. Neither result replaces the complete quality assessment.